Fuse 25A 1-pole tripping characteristic B 6kA 230/400V
€6.59
Ready for shipping, delivery in 48h
Product information "Fuse 25A 1-pole tripping characteristic B 6kA 230/400V"
Number of poles: 1 (1 TE / division unit)
Tripping characteristic: B
Rated current: 25A
Voltage:
Voltage type: AC
Rated voltage: 230/400V
Insulation voltage: 500V
Supply voltage: 50/60Hz
Current:
Switching capacity current: 6kA according to EN 60898, IEC
Protection class:
Protection class: IP20, with connected conductors
Dimensions:
Height: 83mm
Width: 18mm
Depth: 76mm
Installation depth: 70mm
Conductor cross-section: 0.75mm² to 35mm²
Product approval:
halogen-free
silicone-free
sealable
The 25A single-pole fuse with tripping characteristic B is one of the typical fuses in private households and trips from 5 times its rated current of 25 amps. Fast-acting B25 fuses are therefore ideal for lighting circuits and sockets that supply typical household loads. For example, household appliances such as refrigerators, televisions, washing machines and more. As a 25 ampere fuse, this circuit breaker is also suitable for consumers with a slightly higher load, e.g. for a cooker or for the pre-metering fuse.
B circuit breakers protect cables, appliances and people from damage. This circuit breaker is designed for applications up to 6kA and offers effective personal and system protection through safe disconnection in the event of an overload or short circuit.
A bimetallic thermal release trips in the event of an overload (overcurrent), as it bends due to the heat generated when the current is too high. After cooling down, it returns to its original position. This is a major advantage over conventional fuses, which had to be replaced after melting once. The fuse was then literally blown. After tripping, this circuit-breaker can simply be switched on again using the switch lever.
A coil serves as an electromagnetic trigger and trips in the event of a short circuit. The resulting arc is channelled into the extinguishing chamber. The free release ensures that the circuit breaker trips even if the lever is blocked or held up. After tripping, this type B circuit-breaker can be switched on again immediately. If this happens before the fault in the circuit has been rectified, the trip unit will trip again without any danger to persons.
The 25A fuse is also suitable for the quick and easy installation of additional components such as auxiliary current and fault signalling switches. The miniature circuit-breaker can also be combined with shunt releases, undervoltage releases and fire protection switches.
Tripping functions of the B25 automatic circuit breaker:
Overload tripping: this function trips the fuse if the rated current is greatly exceeded over a long period of time. This happens when a bimetallic switch inside trips and switches off the circuit breaker. When the switch trips depends on the level of the overcurrent. With this B25 fuse, the rated current must be exceeded 5 times.
Short circuit tripping: if a short circuit occurs, current flows through a magnet in the circuit breaker, which then trips within milliseconds to ensure personal and system protection.
Manual tripping: the circuit breaker can also be switched on and off manually at the fuse box. This switches off the circuit, e.g. to carry out work on the cable or motor.
To make it easier to insert conductors, the miniature circuit-breaker has a rectangular terminal design to accommodate pin busbars together with conductors up to 35 mm². You can buy other miniature circuit-breakers with other rated currents or C circuit-breakers with characteristics B and C at favourable prices in our shop.
| Auslösecharakteristik:: | Typ B |
|---|---|
| Stromstärke: | 25A |